{"product_id":"amana-eden-occupancy-sensor-dd01e","title":"Amana® Eden Occupancy Sensor DD01E","description":"\u003ch2\u003eAbout This Product\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe occupancy sensor is a combination door-switch and room motion sensor powered by 2 AAA batteries that are included in the kit.\u003c\/li\u003e\n\u003cli\u003eOnce wirelessly linked to Amana® Eden PTAC, the occupancy sensor monitors the room.\u003c\/li\u003e\n\u003cli\u003eWhen the room is unoccupied, the sensor automatically activates the temperature set-back function on the in-room PTAC. The setback function is a part of the Eden standard Energy Management System (EMS) in the Eden PTAC control board.\u003c\/li\u003e\n\u003cli\u003eThe Eden EMS software can be set in up to 100,000 set-back combinations to maximize energy savings and is programmed through either the remote thermostat or the platform controller.\u003c\/li\u003e\n\u003cli\u003eThe sensor communicates to the Amana Eden suite of devices via an encrypted 2.4 Ghz signal using the 802.15.4 standard.\u003c\/li\u003e\n\u003cli\u003eFor the door sensor to operate, the in-room PTAC must be equipped with a Eden gateway antenna.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecs \u0026amp; Details\u003c\/h2\u003e\n\u003cdiv id=\"specTables\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003eOVERVIEW\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAmana®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDD01E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eEden™ Occupancy Sensor \u0026amp; Door Switch Combination Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eEden™ Wireless Energy Management System (EMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003ePassive infrared (PIR) motion sensor with magnetic door switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eBattery powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eWireless, to the PTAC's DT01 antenna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eSelf-installable; no wiring to run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eHOW IT WORKS\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOccupancy Detection\u003c\/td\u003e\n\u003ctd\u003eInfrared sensor and door switch determine when the guest room is occupied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Saving\u003c\/td\u003e\n\u003ctd\u003eWhen the room is empty, signals the PTAC to move through programmable temperature set-backs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExample Set-Backs\u003c\/td\u003e\n\u003ctd\u003e2° after 30 min, 4° after 1 hr, 8° after 3 hrs (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Configuration\u003c\/td\u003e\n\u003ctd\u003ePTAC control automatically activates its energy management routine once the DD01E is installed and bound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Savings\u003c\/td\u003e\n\u003ctd\u003eUp to 35% or more PTAC energy reduction as part of the Eden system*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnet Spacing\u003c\/td\u003e\n\u003ctd\u003eCenter of the magnet must be 15\/16\" from the sensor mounting plate (alignment guides on the bottom of the DD01E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnet Positions\u003c\/td\u003e\n\u003ctd\u003eA, B or C, selected to achieve the 15\/16\" spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor Test\u003c\/td\u003e\n\u003ctd\u003eGreen light shows when the door is closed and turns off when it opens; verify before binding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevices per PTAC\u003c\/td\u003e\n\u003ctd\u003eOne DD01E per Digi Smart™ PTAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBinding\u003c\/td\u003e\n\u003ctd\u003eIf a DS01 wireless thermostat is also used, both devices must be bound in the same learn operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eSYSTEM REQUIREMENTS\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired on PTAC\u003c\/td\u003e\n\u003ctd\u003eDT01 wireless gateway antenna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Units\u003c\/td\u003e\n\u003ctd\u003eAmana® Digi Smart™ \/ Eden-ready PTACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith Front-Desk Platform\u003c\/td\u003e\n\u003ctd\u003eIf using the DL01E controller, room numbers must be programmed in the PTAC before binding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks With\u003c\/td\u003e\n\u003ctd\u003eDS01 wireless thermostat, DT01 antenna, DL01E web platform controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Amana","offers":[{"title":"Default Title","offer_id":50335625740391,"sku":"DD01E","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/5473\/4183\/files\/door-sensor1-bw.jpg?v=1790512600","url":"https:\/\/ptacs.co\/products\/amana-eden-occupancy-sensor-dd01e","provider":"PTACS.CO","version":"1.0","type":"link"}