Skip to product information
Amana® Eden Occupancy Sensor DD01E

Amana® Eden Occupancy Sensor DD01E

SKU: DD01E

About This Product

  • The occupancy sensor is a combination door-switch and room motion sensor powered by 2 AAA batteries that are included in the kit.
  • Once wirelessly linked to Amana® Eden PTAC, the occupancy sensor monitors the room.
  • When the room is unoccupied, the sensor automatically activates the temperature set-back function on the in-room PTAC. The setback function is a part of the Eden standard Energy Management System (EMS) in the Eden PTAC control board.
  • The Eden EMS software can be set in up to 100,000 set-back combinations to maximize energy savings and is programmed through either the remote thermostat or the platform controller.
  • The sensor communicates to the Amana Eden suite of devices via an encrypted 2.4 Ghz signal using the 802.15.4 standard.
  • For the door sensor to operate, the in-room PTAC must be equipped with a Eden gateway antenna.

Specs & Details

OVERVIEW

Brand Amana®
Model DD01E
Product Eden™ Occupancy Sensor & Door Switch Combination Device
System Eden™ Wireless Energy Management System (EMS)
Sensor Type Passive infrared (PIR) motion sensor with magnetic door switch
Power Battery powered
Communication Wireless, to the PTAC's DT01 antenna
Installation Self-installable; no wiring to run

HOW IT WORKS

Occupancy Detection Infrared sensor and door switch determine when the guest room is occupied
Energy Saving When the room is empty, signals the PTAC to move through programmable temperature set-backs
Example Set-Backs 2° after 30 min, 4° after 1 hr, 8° after 3 hrs (adjustable)
Auto-Configuration PTAC control automatically activates its energy management routine once the DD01E is installed and bound
Estimated Savings Up to 35% or more PTAC energy reduction as part of the Eden system*

INSTALLATION

Magnet Spacing Center of the magnet must be 15/16" from the sensor mounting plate (alignment guides on the bottom of the DD01E)
Magnet Positions A, B or C, selected to achieve the 15/16" spacing
Door Test Green light shows when the door is closed and turns off when it opens; verify before binding
Devices per PTAC One DD01E per Digi Smart™ PTAC
Binding If a DS01 wireless thermostat is also used, both devices must be bound in the same learn operation

SYSTEM REQUIREMENTS

Required on PTAC DT01 wireless gateway antenna
Compatible Units Amana® Digi Smart™ / Eden-ready PTACs
With Front-Desk Platform If using the DL01E controller, room numbers must be programmed in the PTAC before binding
Works With DS01 wireless thermostat, DT01 antenna, DL01E web platform controller

You may also like